Conference room AV checklist: display, speakers & mics

SONTRA Project TeamPublished Updated 2 tables
Conference room with ceiling loudspeakers and a presentation screen

A conference room is judged by the meeting, not by the rack. If the far end cannot hear the room, if the display is too small for the last row, or if the microphones pick up the ceiling fan, the equipment list does not matter.

This checklist follows the room from the seats outward. It is written for meeting rooms, boardrooms and lecture spaces that have a real floor plan.

What room data do you need?

Record the room length, width, finished ceiling height, seat count and table layout. Add the window wall, the glass partitions, the HVAC diffusers and the door positions. These are the inputs that decide display size, loudspeaker placement and microphone count.

A divisible room needs a separate data set for each configuration. A room that can be split into two must work as two rooms and as one.

Room data

InputWhat to recordWhy it matters
DimensionsLength, width and ceiling heightDisplay size and coverage
SeatsCount and table layoutMicrophone count and sight lines
SurfacesGlass, hard wall, carpet, ceilingReverberation and echo
HVACDiffusers and return grillesNoise floor and microphone placement

How large should the display be?

Display size is a sight-line calculation, not a diagonal-inch preference. Measure the distance from the furthest seat to the screen and check the text height. A 75-inch screen in a long room may be less readable than a 98-inch screen or a projection system.

For a hybrid meeting, add the camera position and the far-end view. The display is also the window to the remote participants; it needs to be visible from the table and from the presenter position.

Where should the loudspeakers go?

Speech intelligibility is the target. Use ceiling loudspeakers distributed over the seating area, or wall/column loudspeakers aimed at the listeners. Avoid placing loudspeakers behind the presenter or above the first row only.

The number and tap setting depend on the ceiling height and the reverberation. A glass-walled boardroom needs more attention to the first reflection than a carpeted training room.

How many microphones do you need?

Count the people who need to speak, not the people in the room. A boardroom may need one microphone per two seats; a lecture hall may need a lectern microphone, two audience microphones and a wireless handheld.

Decide whether the system is discussion, voting or interpretation. Each function adds units and cabling. A paperless or voting system also changes the table layout and the control room.

How should control and connectivity be planned?

The room should start with one button, not five remotes. Define the sources: laptop, wireless presentation, video conferencing, document camera and room PC. Then choose the switcher, the control panel and the wall plate.

For a hybrid room, confirm the camera, microphone and speaker path with the video platform. A USB room device is not the same as a full AV system with a matrix and a control processor.

How do you check speech intelligibility and echo?

Before the equipment is installed, check the room acoustics: reverberation, background noise and flutter echo. Hard parallel walls and glass can make a good system sound poor.

Use the room data to set the loudspeaker aim and the DSP preset. If the room needs acoustic treatment, raise it before the equipment order. A DSP cannot remove a long reverberation time.

What should be checked at commissioning?

Test the room as a meeting, not as a list of devices. Walk the far end through a call, sit in the last row, and check the display, the speech level and the microphone pickup.

Commissioning record

TestMethodRecord
DisplayRead the smallest text from the last rowSeat position and result
SpeechMeasure the level at the last rowTarget and measured value
MicrophonesTest every seat and the presenterWorking units and gain
Hybrid callJoin a remote meeting from the roomAudio, video and share

What should you send for a quotation?

Send the floor plan, the seat count, the table layout, the ceiling height and the use case. Add the existing display, camera and platform if the room is a retrofit.

With those inputs we can return a display size, a loudspeaker layout, a microphone count and a control concept. The final model list follows the room, not the other way round.

A conference room works when the display, the loudspeakers, the microphones and the control are designed as one room. The equipment list should be the last document, not the first.

Related products

Frequently asked questions

Frequently asked questions

What size display do I need for a meeting room?

Start from the distance to the furthest seat and the smallest text that must be read. A larger room or a deeper table needs a larger display or a different display type.

How many microphones does a boardroom need?

Count the people who need to speak and the table layout. A common starting point is one microphone per two seats, plus a presenter or lectern microphone.

Do I need ceiling speakers or wall speakers?

It depends on the ceiling height, the room shape and the reverberation. Distributed ceiling speakers are common in low rooms; wall or column speakers can work in high or reflective rooms.

Can I use the room’s TV speakers for conference audio?

For a small huddle room, possibly. For a boardroom or a hybrid meeting, a separate loudspeaker system with speech-optimised coverage is usually clearer.

What is the difference between a discussion system and a conference microphone system?

A discussion system controls who can speak and may include voting or interpretation. A conference microphone system is the microphone and audio path; the two often overlap.

What should a conference AV quotation include?

Display, loudspeakers, microphones, control, cabling, mounting, configuration and commissioning. For hybrid rooms, add the camera and platform interface.

Related pages

Put the article’s decision order to work on your project

One brief, one combined proposal

Send the building once. Get the whole system back.

Tell us the building type, zones, room sizes, ceiling height, seat or table count, fire interface and any ODM/OEM requirement. Our own factory and system team return one combined proposal: equipment schedule, interface list and open questions.

Reply within 48 hours · drawings welcome · no obligation