PA line · core

PA system control & mixer amplifiers

Broadcast hosts, zone controllers, mixer amplifiers and IP amplifiers for background music, paging and emergency override — specified as one signal chain.

BGM & public addressOwn-factory productODM / OEM
Rack-mount mixer amplifiers with zone selection and level metering

Representative image. Final finish and configuration are confirmed with the quotation.

Key values: 100V · 4–64 · 32 · Analogue / IP

100V
Line voltage
4–64
Zones per host
32
Alarm inputs (ref.)
Analogue / IP
System types
Rack-mount mixer amplifier pair
IP network amplifier with front display
Touchscreen paging console

Reference hardware · final finish and tap setting confirmed with the quotation

Overview

The head end that decides how the building behaves.

A public address system is judged at the head end. This is where the music source, the paging microphone, the fire-alarm interface and the zone schedule meet. If the head end cannot prioritise them cleanly, the loudspeakers cannot fix it.

We specify the control layer as a chain: source and message storage, priority logic, zone matrix, power amplification and monitoring. The chain may be analogue, IP-networked or a hybrid of both. The choice is driven by the number of zones, the distance between buildings, the fire-alarm interface and whether the client wants a central rack or distributed racks.

The reference design for a 23-storey mixed-use tower used 25 loudspeaker circuits, 1,080 loudspeakers and about 4.2 kW of connected tap load. That is the scale at which amplifier headroom, circuit protection and standby policy stop being details and start being the design.

Manufacturing & system package

Manufactured in our own factory. Available as a standalone family, or combined with PA, conference, AV and ballroom families into one complete system package and one combined proposal. ODM and OEM programmes available.

Priority that is written down

Emergency broadcast overrides paging, paging overrides background music. The priority table is part of the submittal, not an afterthought in the menu.

Zone matrix, not a volume knob

Each zone is a separate address with its own source, level and mute behaviour. Zones can be grouped for all-call without losing individual control.

Amplifier headroom

Connected tap load is summed per circuit, then headroom is added for programme peaks and ageing. Amplifier size follows the schedule, not a rule of thumb.

Monitoring and fault reporting

Pilot tone, circuit monitoring and amplifier fault contacts are specified where the building needs to know a line has failed before an evacuation.

Reference specification

What are the reference specifications and selection rules?

The table is a design reference, not a model datasheet. The quoted model carries the final ratings.

ItemReference value or guidance
Line voltage100V
Zones per host4–64
Alarm inputs (ref.)32
System typesAnalogue / IP
System typesAnalogue 100V, IP-networked, hybrid
Typical zone count4–64 zones per head end
Loudspeaker line100V constant voltage
Reference host6U rack, dual network ports, 15 in touch display
Fire interface32 alarm inputs, 2 alarm outputs (reference)
Emergency priorityHard-wired override, all-call or per-zone
Small single-building systemA mixer amplifier with 4–6 zones, one paging microphone and a local music source is usually enough. Keep the fire interface hard-wired and independent of the network.
Multi-building campusUse an IP head end with distributed IP amplifiers. The network carries audio and control; each building keeps a local amplifier and loudspeaker circuit.
Tower with many risersSplit the loudspeaker load by riser and fire compartment. Sum the tap load per circuit, add headroom, then choose amplifier channels per riser.
Existing analogue systemA hybrid head end can keep working 100V loudspeaker circuits while adding IP paging and remote control. This is usually the lowest-disruption retrofit path.
Voice alarm requirementWhere EN 54-16 or a local equivalent is required, the control and amplification path must be part of the certified scope. Confirm the standard and the accepting authority before the quote is fixed.

Model range

Representative models with photos

Only models with an available product photo are listed. The full range, model-level datasheets and certificate scope are supplied with the quotation. Brand names are not used on this site.

Request the full model list
PhotoModelTypeNote
BL-E3001-H — IP network broadcast control hostBL-E3001-HIP network broadcast control host6U rack host with dual network ports and touch display.
IP-S1 — IP network broadcast serverIP-S1IP network broadcast serverServer platform for IP audio, zones and terminal management.
D4100 — Power amplifierD4100Power amplifierRack amplifier for speech and music reinforcement; model rating confirmed with quotation.

Representative models only. Key electrical, acoustic and certification values are confirmed in the model datasheet and the quotation.

Questions

Frequently asked questions

The questions that usually decide the scope: loudspeaker count, amplifier size, fire interface, certification and who installs the system. If your question is not here, send it with the building data.

Ask an application engineer

How much amplifier power does a 100V line need?

Add the tap wattage of every loudspeaker on the circuit, then add headroom for programme peaks and ageing. A common starting point is 1.25–1.5 times the connected tap load, but the final figure depends on the programme material, the transformer taps and the acceptable distortion. The calculation is returned with the bill of materials.

Can one head end serve several buildings?

Yes, if the buildings are on a reliable network. An IP head end can send audio and control to distributed IP amplifiers, while each building keeps its own loudspeaker circuits. The network design, switch quality and fallback behaviour have to be agreed before the topology is fixed.

What happens when the fire alarm activates?

The fire interface takes priority over all other sources. The usual arrangement is a hard-wired trigger per zone or group, a pre-recorded evacuation message, and an override that cannot be cancelled from the paging microphone. The exact sequence is agreed with the fire-alarm supplier and the accepting authority.

Do you supply the rack and the wiring?

We supply the head-end equipment, the rack layout and the circuit schedule. Field wiring, containment, termination and statutory commissioning are carried out by the local contractor unless a different scope is agreed in writing.

Can the system report a failed loudspeaker line?

Yes, where the specification calls for it. Pilot-tone monitoring, impedance monitoring and amplifier fault contacts are available. The level of monitoring is a design decision: it adds cost and commissioning time, so it is matched to the building risk and the fire strategy.

Next step

Send the room, not the model

Tell us the building type, the zones, the ceiling height and the fire interface. We will check whether this family fits before we quote it, and show how it combines with the rest of the system in one proposal.

  • Coverage and tap-load calculation
  • Interface list for fire, paging and network
  • Certificate scope confirmed per model
  • ODM / OEM or private-label requirement

Project inquiry

Ask about Control & amplifiers

Send the room or building data once. We return one combined proposal covering PA, conference, ballroom and AV, with the equipment schedule, interface list and the questions that still need an answer. ODM and OEM inquiries are welcome. Drawings are welcome but not required.

Fields marked * are required. · We use the details only to answer this inquiry.